Loading...
HomeMy WebLinkAbout2864 WHIPTAIL LOOP; 100; FPC2018-0036; PermitPERMIT REPORT Fire Permit Print Date: 02/29/2024 Job Address: 2864 WHIPTAIL LOOP, # 100, CARLSBAD, CA 92010-6712 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel#: 2091201000 Track#: Valuation: $41,161.35 Lot#: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Project#: Plan#: Construction Type : Orig. Plan Check#: Plan Check#: Description: ELEVATE BUILDING B -OFFICE Tl -SPRINKLER 7-100 (17 HEADS) Applicant: EPIC FIRE PROTECTION INC ADAM BOISVERT 765 TURTLE POINT WAY SAN MARCOS, CA 92069-8126 (760) 310-6122 FEE FIRE NFPA 13 or 13R System 7 -100 heads Total Fees: $536.00 Total Payments To Date: $536.00 C cityof Carlsbad Permit No: FPC2018-0036 Status: Closed -Finaled Applied: 02/01/2018 Issued: 02/20/2018 Finaled Close Out: 04/16/2021 Final Inspection: INSPECTOR: Fieri, Dominic FPContractor: EPIC FIRE PROTECTION INC 765 TURTLE POINT WAY SAN MARCOS, CA 92069-8126 {760) 310-6122 Balance Due: AMOUNT $536.00 $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2665 I Inspections: 442-339-2660 I www.carlsbadca.gov \ FIRE SPRINKLER CORPORATION QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT• PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount or fluid. When heat is absorbed, the liquid -.vithin the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. TECHNICAL DATA • See reverse side for Approvals and Specifications. • Temperature Ratings -135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) •Water Working Pressure Rating -175 psi (12 Bars) • Factory tested pydrostatically to 500 psi (34 Bars) • Maximum low temperature glass bulb rating is -67°F (-55°C) • Frame -bronze • Deflector -brass • Screw -brass • Lodgement Wire -stainless steel • • Bulb seat -copper • Spring -nickel alloy • Seal -teflon • Bulb -glass with alcohol based solution, 3mm size QUICK RESPONSE UPRIGHT CONVENTIONAL QUICK RESPONSE PENDENT VERTICAL SIDEWALL GI QUICK RESPONSE HOR~ONTAL LPC/CE SIDEWALL HOR~ONTAL SIDEWALL •SPRINKLER TEMPERATURE RAT/NG/CLASSIFICATION an _ _dCOL0R CODING CLASSIFICATION' AVAILABLE SPRINKLER ORDINARY IN1ERMEDIATE HIGH 4tJ77 AIRPARK DRIVE. STANDISH, MICHIGAN 486SB JULY 2012 A-Z.0 BULB COLOR ORANGE/RED YELLOW/GREEN BLUE N.F.PA MAXIMUM CBUNG TEMPERATURE 969-a46-4583 • FAX989-a46-9231 BULLETIN GL5615, REV. #9 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT. PENDENT• VERTICAL SIDEWALL HORIZONTAL SIDEWALL • CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENOTH, FINISHES 2.8 (39 metric) 4.2 (59 metric) 5.8 (80 metrtc) 7.8 (111 metric) 8.1 (116metrtc) METR)C COWERS IONS ARE APPROXUMTE. 1110RlZONTALSIOEWALL IS 2Wl8". 1 FlNISHES AVAll.ABLE ON SPECW.. OROER.. 112"NPT 112" NPT 112" NPT 112" NPT 3/4" NPT 2 1/4" (5.7cm) 2 114" (5.7cm) Factory Bronze Ct-rome 2 114" (5.7cm) 2 1/4" (5.7cm) 'Ntite Polyester J 2 7/16" (62cm) Slack Potyestor 1.> 1 AVAJLABL.E AS dJl.us USTEO CORROSION RESISTANT WHEN &PECWIED ON ORDER. APPROVALS SlYLE SIN K f'AZAAO' 135°F t55'F 17S'F "2!X1'F ,..-F cl.t.oa FM LPC CE NVC• DOB MOOEt FACTOR src ll8"C 1'rC ll3'C 141-C ME.A 101..Q'Z-E Gl315 2.8 L.H X X X X X X ---X Gl.<215 .., L.H X X X X X X ---X IPRIGHT Gl5615 ~· !HOH X X X X X X X X X X 0La115 ,,, !HOH X X X X X X ---X Gl8tt6 a, !HOH X X X X X X X X X X Gl2IIOt 2.8 L.H X X X X X X ---X ii 4.2 L.H X X X X X X ---X Pa.oENT ~· ll-fOH X X X X X X X X X X , ... IHOH X X X X X X X --X GU108 .. , ll-fOH X X X X X X X X X X VER'TlCAl Gl.51132 ~· L.H X X X X X X X --- SO:WAU1 GUt33 O.t L.H X X X X X X ---- GU820! 2.8 L.H X X X X X X ---X HlR2DNTAL GI.C2211! 4.2 L.H X X X X X X ---X SClEWAll Gl.SU21J t ~· IHOH X X X X X X X --X CllS027' 5.6 ll-fOH X X X X X --X X -GUt27! at !HOH X X X X X X ---- CONVENT10NAL GlSB24 5.8 !HOH X X X X X --X X -(OlDSlYlE) Gl.0125 a, !HOH X X X X X --X X - 1SPR!NKL£RS StW.l BE UMITEDAS PEA THE REQUIREMENTS OF NFPA13AND ANYontER RELATED DOCUMENTS. 5HOR1ZONTAL SIDEWALL dJlJ.a USTED FOR DEFLECTOR ,4• TO 1'Z' BELOW THE CEJUNG. FM APPROVED~ TO 8" BELOW THE CEILJt.lG. •IHSTALLINACCORO.-.NCE TO BS5301ANOANYOTHER RELATED DOCUMENTS. 'PENDENT VERTICAL Sl>EWAU. dA.i.a LISTED FOR 8' MIN. SPACING. ftJPRIGHT VERTIC.AL. SIDEWAI.L dJlA.-USTEO FOR I' MIN. &PACING. OH. ORDINARY HAZARD utUGHT~O "112"NPT ORDERING INFORMATION SPECIFY -Quantity • Model Number • Slyle "'Oriftee .. Thread Sizes • Temperature • Finishes desired • Ouantily -Wrenches -PIN 325300 (1/21; PIN 312366 (LO.) 1L .. BE ' ~ F!RE SPRl!lnEi CORPORATIOII JUNEZ.012 GLOBE-PRODUCT WARRANTY Gk>be agrees to repair or replace any ot its own manutactwed products found to be defective in material or workmanship for a period of one year from date of shipment For specific details of our ..wrranty please refer to Price Li.st Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 i -01..A.r,l.'ff)-(JL(C, PRINTED U.SA www.9iooespm1<1er.com BULLETIN GL5615, REV. #9 Fireloc~ V34, K8.0 Model V3428 Quick Response Extended Coverage/light Hazard (ECLH) Pendent and Recessed Pendent I Approvals/listings: ,@ • ... , .. St-I: • ~ P, ~-~ 10 Jl f;.,, mott, de:.ai . .i. Product Description: These Model V34 ECLH sprinklers are designed with a KB.O orifice size and provide added coverage at normal light hazard operating pressures. Each sprinkler Is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly ettort. This sprinkler is available in various temperature ratings (see chart on page 4) and finishes to meet many design requirements. Coveraee Extended spray coverage is up to 400 square feet (37.2 sq. m) per NFPA 13. Job/Owner System No. j Location Contracto, Submitted By Date '\h:tauhc' Technical Specifications: Models: V3428 Style: Extended Coverage/ Light Hazard -Pendent, Recessed Pendent Nominal Orifice Size: %'/14 mm K Factor: 8.0 lmp./11.5 S.1.1 Nominal Thread Size:¼' NPT/20 mm BSPT Max. Working Pressure: 175 psi/1200 kPa 40.78 factory Hydrostatic Test: 100% C 500 psi/3450 kPa Min. Operating Pressure: 7 psi/48kPa Temperature Rating: See chart 1 For K-factor wnen p,es~re is measu,ed in BM, multiply S.I. units t,,,, 10.0. r·· i '·-, i ··, .. : ......... I 1 ==---' ~ • ---==~ 1· : i ~ ! ~l•., •• , .. , ·-,._j Exaggerated for clarity Eneineer Spec Section Paragrapn Approved Date victaulic.com I Sprinklers I Firelock• I V34, K8.0 I Publication 40.78 , victaulic.com I Sprinklers I Firelock• I V34, KB.O I Publication 40.78 Material Specifications: Pendent Deflector. Bronze per UNS C22000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon' tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Approvals/llstlnp: APPROVALS/US TINGS Orifice Size (Inches) Orifice Size (mm) Nominal k Factor Imperial Nominal K Factor S.I.' Response Deflector Type Approved T~puarure fhtings F•tc• •• cUlus Model V3428 V3428 17/32" 1◄ 8 11.S Quick Pffldent 17/32' 1◄ 8 11.S Qukk RKU~ Pendent Approved Teml)ffatUfe Ratlnp ~,c.•., 135•f/S7•C 1ss•Ff68-C 11s•Fm·c 20o•f19rc ns·F1s1-c 155"1'/68-C 175•ffWC 200-F/93-C Llshnp and approvat as of pnntin&, Not all tempe•,turc talin& combmatioos a,e Apprcwed o, Ur.ed. Chec11: Vlctoulic to, specffic combinations. ' Fo, K-Factor when ~ssore iS measued in S,r, multiply S,1. uruts by 10. Llaht hazard ant)'. Accessories: Installation Wrench Open End: V34 Recessed: V34 Sprinkler Finishes: Plain Brass Chrome Plated White Painted Custom Painted VC-2503 'Teflon Is• reststered lrademaril of DuPont Co. JUL Listed ~nd FM Approved fo, corrosion resistance. Dimensions: ~ICtlingT11t ~ rln;.sN!C!Surf,ce T l'/,"/29,rrn ~ICt,lr,gT,le lW~Smm "1LJ \.An~5'Jrl.c.r I'/ 25mm 1 Typka1ce:!lngTilt f,nlshfd Sl.rfacr ~alCe-~ng· Flnls,.rd Surf~t , victaulic.com I Sprinklers I Firelock• I V34, K8.0 I Publication 40.78 Room Size: Sprinkler Performance Flow And Preuure (Minimum) l V3428 Room Size Flow Ralt End Sprinkler Pressure GPML/1.PM PSl/kPa fl, I Ft. UL UL mxm • 16X 16 26 10.6 4.9X4.9 98 73.1 18X 18 33 17.0 S.SXS.5 125 117.2 20X20 40 25.0 6.1 X6.1 ,so 172A Distribution Patterns: .. "'"' , .. Models V3428, K8.0 ECLH Pendent and Recessed Pendent Distribution Patterns -Trajectory -~---··-..... .. ...... ··, .... ··, .. , ··,. ·, ··,. ·, ··,. ·, ··,\ ... Response V3428-Qukk NOTES: .. Um ,. lAm ,.. ,..., Mlnlumum Installation Spaclnc Feet/meters 8.0 2.4 " 171'11 A. Data ShoWn Is approunate and can vary cue to d ffcrenus In ln51allatloo. \. \ .. ,.. S.Sm l6GPIIII 96llM IJGPM 1249LPM ...... lSIAlPM B. These araphs ilustrate app,Clll'.lrr\a trajectones, noor-wettine. and wall-wettlna patll!:ms for these spe,ciflc Vlctauhc frel.Oek AUtomatx: Spmklers, They 11'8 p-tWlded as Information f0t suloance In ~ire obstructkJns 10 spfinklers and snould "'IOt oe used n fT'llnirrtJm spm,lder spiCll"8 rules for imtala!lon. Refer to the appropriate NFPA Natk>nal F"u Code or the Authority Having Jlllsdicbon I-or specific Wormation repdmfl: obstructions, spatil& llmitatJons and area d CDM38' reQWel'TWl1$, Failure to follow these guld@lines oou6d advfflely affect It'll! performance of the sprinkler and MIi VOid a•~. Appron!s and Warranbes. C. All patterns are symmetrical to lhe centerline of the wall!!rway. , victaulic.com I Sprinklers I Firelock• I V34, K8.0 I Publication 40.78 Ratings: All glass bulbs are rated for temperatures from -65'F (-54'C) up to those shown in adjacent table. Temperature --Frc. Vlctaulic Nominal Part Temperature Maximum Ambient Temperature Sprinkler Temperature Classlfication Ordinary ktentificationj1 fbtlnc A 135"F/57'C -!OO'F/38'< Glau Bulb Colo, Orange Ordinary Intermediate Intermediate Available Wrenches: Pendent Recessed Pendent ~ C - ......... 155"F/68"C 100'F/38'C Red 1750f/79"'C 150°F/65°C Yellow 200"F/93°C 1 SO°F/6S°C Green Open End V34 Recessed V34 V34 .A. WARNING .. • Always read and understand Installation, care, and maintenance insbuctions, supplied with each boJ of sprin- klers, befOfe proceedlnc wtth lnstallatlon of any sprtnklen. • Always wear safety ct.asses and foot protection. • Oep,essurize and drain the piplne system before attemptina to install, remove, or adjust any Victaullc pipinc products. • lnstallaUon rules, especially those l<WffllirtC obstruction, must be strktly followed. • Painting. plating, or any re-coatlnc of sprinklers (other thin that supplied by Victaullc) Is not al~. Failure to ~low these Instructions could result In serious per$0nll injury and/or property dam1ce, The owner is responsib~ for maintaininc the fire protecttOn system and devices in proper operatina condition. For minimum maintenance and Inspection requirements, refer to the current National Fire ProtecUon Association pam- phlet that duc:rtbes care and malntemince of 1prinkler systems. In addition, the authottty h1vtn1 Jurisdiction may have addttlonal maintenance, testln&, and Inspection requirements th.at mu5t be followed. If you need additional copies of this publication, or if you hive any questions about the safe installation of this product, contact Victaullc Worid Headquarters: P.O. Bu 31, Easton, Pennsylnnla 18044-0031 USA, Telephone: 001-610-559-3300, - ., Relttertee ,l'IOl.ltl alw.yl be made lo ll'M ,4{, VICllullc. flrelock AulomatiC Sprlnktets Installation and Maln~l'lllnce Sheet for the7iioduct ~ 11e lnsllfln&. Thit l'lstM!Jtlon sheet II indl.tclt;d wkh uch shil)mel'll ol Vlctaulic products tor c~ 1nsi.Katlon #Ml assemoty data, ,no 15 1v111ible 1n POf lormtt on ou1 '#'lt>Sile II vict.tuic.cam. This l)rOOUCI 1MII bt m1nu'actvred ~~«to Vlctaullc: speciflcatlons, M Pl'OOUcts WMlm)' Rater 10 tl'lt W1rnnty MC?ion ol IN curr111 Pfa Ust Of cOl'ltllct VlcUulic tor dMaib. to 01 lnlbllod In ICCOffla(ICS with COOenl Vktaulic nsta&lllon/Hwmbl)' Instructions. VoclaiAlc reser.oes ttw: ,111:N lo ctwnae l)RldiJct ,pecllk:1tions, oesp o!Wf sandard eq.Jlpmenl: without nodes and witl!Oul 1ncurm1 obAptlon, ,_ Voctaulic: ,s • re,iswed 11eoemai-1t o4 'lictluk Co,rptny, I 'JIKINCG ® TECHNICAL DATA Page 1 of6 ESFR PENDENT SPRINKLER VK500 (K14.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlklngcorp.com Viall the Viking website for the latest edition of this technical data page: www.vlklnggrouplnc.com 1. DESCRIPTION Viking Earty Suppression Fast Response (ESFR) Pendent Sprinkler VKSOO is a fast response fusible element type sprinkler designed lo< early fire suppression. Wlth a 14.0 (202 metric') nominal K-Fecto< and special deflector, this sprinkler produces large, higl>-momentum water droplets In a hemispheric pattern below the dellecto<. This permits penetnltlon of the fire plume end direct wetting of the burning fuel surface while cooling the atmosphere early In the development of a high-chaUange ftre. lllklng VKSOO ESFR Pendent Sprinklers may be used in the protection of orninary types of sto,age. However, they are primarily Intended to protect the following types of stor- age, which tend to produce severe-challenge fires: palletized and solid plle storage and single, double, multiple row, and portable open rack sto,age (no open-top containers or solid shelves). Viking ESFR Pendent VKSOO Sprinklers provide protection of most common sto,age materials, Including: -Encapsulated or unencapsulated Class I, II, Ill, and IV commodities•. --Cartoned and uncartoned unexpanded plastics". -Cartoned and uncartoned expanded plastics". • Refer the Approval Charts and Design Criteria on pages 3--4 for cULus Listing and FM Approval requirements that must be folklwed. In addition, some storage arrangements of rolled paper, aerosms, and rubber tires may be protected by Viking ESFR Pendent Sprinkler VKSOO. 2. LISTINGS ANO APPROVALS •®• cULua Listed: Category VNWH ~ FM Approved: Class 2008 NYC Approved: MEA 89-92-E, Volume 18 VdS Approved: Certificate G4010001 8 CE @ CE Certified: Standard CUAP11.03/03, EC-certificate of conformity 1725-CPD-H0005, ETA-10/0306 CCCF Approved: Approved by the China Certlflcatlon Center for Fire Products (CCCF) The 10284 and 11350, VKSOO, ESFR Pendenl Sprinkler Assembly conforms to the provision of CUAP11.03/03 standard. CUAP11.03/03 approvals are provided by: FM Approvals Ltd. 1 Windsor Dials Windsor, Berkshire, UK. SL4 1 RS Approval Certificate No. Issued Decamber 20, 2010. NOTE: Other lntematlonal approval certificates are available upon request Reier Approval Chart 1 and Doslgn Criteria on page 3 for cULus Listing requirements that must be followed, and refer to Approval Chart 2 and Design Criteria on page 4 for FM Approval requirements that must be followed. 3. TECHNICAL DATA SpeclflcaUona: Available since 2000. Minimum Operating Pressure: Refer to NFPA 13 or FM Global Loss Prevention Data Sheets. Maximum Working Pressure: 175 psi (12 bar). Faciory tested hydrostatlcally to 500 psl (34.5 bar). Thread size: 3/4" (20 mm) NPT Nominal K-Factor: 14.0 U.S. (202 metric") 0 Metric K-fador meesurement shown ls when pressure Is measured In bar. When presue ls measured In kPa, divide the metric K.factor shown by 10.0. Overall Length: 2-7/8" (73 mm) Deflector Diameter: 1-3/4" (44.5 mm) Materfal Standards: Frame Castlng: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-C51000 Form No. F_060198 17.02.02 Rev 17.1 Replaces Form No. F _060198 Rev 16.1 (Added CCCF approved sprinkler.) Page 2 of 6 'JIKINCG® TECHNICAL DATA ESFR PENDENT SPRINKLER VK500 (K14.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Emall: techavcs@vlklngcorp.com Visit the Viking web1ite for tho latest edition of 1h11 technical data page: www.vlkJnggrouplnc.com Seat for Sprinkler 11350: Stainless Stael UNS-531603 Seat and Insert Assembly to, Sprinkler 10284: Copper UNS-C11000 and Stainless Steel UNS-S30400 Bellevtne Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Stainless Steel UNS-531603 Trigger and Support: Stainless Steel UNS-531600 Fusible Element Assembly: Beryllium Nickel, coated wtth black ac,yllc painl Ejector Spring (Sprinkler Base Part No. 11350 only): 17-7 Stainless Steel Orct.r1ng Information: (Also refer to the current Viking price llsl) Orner ESFR Pendent Sprinkler VKSOO by first adding the appropriate suffix to, the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A Temperature Suffix: 165 'F (74 'C) = C, 205 'F (96 'C) • E Fo< example, sprinkler 10284 with a Brass finish and a 165 'F (74 'C) temperature rating= Part No. 10284AC. Available Finishes And Temperature Ratings: Refer to Table 1. AccauorlH: (Also refer to the Viking website.) SprlnkJer Wrenches: A. Part No. 13635W/B (double-ended wrench -Use Side A. Side B is for use with K25.2 ESFR Pendent Sprinkler VK510) Available since 2006. B. Part No. 10285WIB (no longer available) Sprinkler Cabinet: Twelve-need capacity: Part No. 01725A (available since 1971) Ordinary 165 'F (74 'C) Intermediate' 205 'F (96 'C) Sprinkler Finish: Brass Footnotes ' The sprinkler temperature rating Is stamped on the deflector. None 150 'F (65 'C) Whits 2 8as&d on NFPA·13. Other limlts may appty, depending on fire k>adlng, sprinkler location, and other requirements of the Authority Having Jurisdiction. Ret.r to specific lnstallatk>n standards. , The lntennedlate temperature rating fs available for Sprinkler Base Part No. 10284 only. WT9nchftat C, Uae Side A for VK500 Figure 1: ESFR Pendent Sprinkler Wr9nch 13635WIB Form No. F _060196 17.02.02 Rev 17.1 2-718" (74mm) 1-7/16" (37mm) 1-7/16" (37mm) ~,:t- Sprfnkler 10284 Shown Flguro 2: ESFR Pondent Sprtnkler VK500 Dimensions Page 3 of 6 \IIKINCii® TECHNICAL DATA ESFR PENDENT SPRINKLER VKS00 (K14.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877°384-5464 Fax: 269-818-1680 Email: techsvcs@vlklngcorp.com Visit the Viking website for the latest edition of this technical data page: www.vlklnggrouplnc.com Base Part Number1 10284 11350 19855 21360 SIN VK500 VK500 VK500 VK500 NPT Thread Size lnchH mm 314• 20mm 314• 20mm 314· 20mm -20mm Approval Chart 1 (UL) Nominal K.factor .... ___ _ _,11,_(12...,_ Overall Length U.S. metric' lnchH mm I c.Ulu•• 14.0 -2-718 73 I A1, 81 -202 2-718 73 -202 2-7/8 73 -202 2-718 73 Approved Temperature Ratings A· 165 'F (74 'C) 8 • 205 'F (96 'C) FoolnotH ' Base part number shown. FOf complete part number, refer to the price list. Llltlnga and Approval,,.. (Refer aJ.o to °"'"" Crttefta ~low.) NYC' I VdS I LPCB A1 A1 A1 Approved Finish 1 -Brass A1,B1 A1,B1 :af·1 A1 A1 'Metric K-Fac1Dr measm,ment shown Is when p<eSSU'e ls measured In bar. ""1e<1 pressure is measured In kPa, divide the metric K-Faclo< shown by 10.0. , This chart shows listings and approvals available et the time of printing. Other approvals may be in process. • Refer to the latest standards of NFPA 13 and the latest VdS standards. 'Listed by Underwriters Laboratories Inc. for use In the U.S. and Canada. 1 Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vot 18. '(E CerUlied, Slandaro CUAP11.03/03, ECA:ertifocate of confonnity 1725-CPO-H0005, ETA-10/0306. DUKJII CRITIRIA tuLI (All0 ,_IOApplovll OWi 1 above.) cULu1 Ll1Hne Rtaulr:1m101I· ESFR Pendent Sptinkler 10284 ~ cULus Listed as Indicated in Approval Chart 1 for Installation In accordance with the latest appropriate NFPA stan-daros 0ndudlng NFPA 13) for ESFR Pendent K14.0 (202 bar) Sprinklers, for: • Protecting rack storage of certain specified materials up to 35 ft (10.7 m) high In bulldlngs with 40 ft (12.2 m} high ceMklgs with NO In-rack sprin-klers. • NFPA 13 Indicates the fotlowlng for ESFR pendent sprinl<Jers having a 14.0 nominal K-Factor: PO$ltion the~ a maximum of 14" (356 mm) end a minimum of 6" (152 mm} below the ceHlng. • The minimum area of coverage allowed per sprinkter la 64 ftZ {5.8 m1} per NFPA 13. Maximum Roof or Celling Slope: 2 In 12 (167 mmtm or 9.5 degrees). Sprinkler Position: Approved for use only in the pendent position. Align the deflector paratlel wtth the ceiling o, roof, Syatem Type: Wet. systems onty. Deflector Distance from Walla: At least 4· (102 mm) from walls, and no more than one-half the atkJwable distance permitted between sprinklers. Clearance from Deflector to Top of Storage: At least 35· {914 mm}. Maximum Dlatance BetwHn Sprtnklera: The maximum area of coverage albwed per sprinkler is 100 ft2 (9.3 ml}"". • For butldlngs OV81' 30 ft (9.1 m) high, spacing between sprlruders and/or branch lines must be from 8 to 10 ft (2.4 to 3.1 mr•. • ~=~r ~~::,~~ ~! ~~·~·:' =~i;= ;~ :iQ.~ and/« branch Unes Is 8 to 12 ft (2.4 to 3.7 m), provfded the area .. ::f~!°S:-a~:~=:~~:i: rs~'=k~tlons from the maxtmum sprinkler spacing rules above, to ellmlnate obstructlons created Minimum Area of Coverage: The minimum area of coverage allowed per sprinlder ls 64 ftZ (5.8 m2). __!!ote: If the ceUing Is beam and girder or panel construction, locate sprinkler'I In the bays rather than under the beams. IMPORTANT: Always refer to Bulletin Form No. F _091699 • Core and Handling of Sprinklers. Viking ESFR Pendent Sprinklers are to be Installed In accordance with tho latest edition of Viking technical data, the latest standards of VdS, NFPA, and any other Authorttles Having Jurisdiction, and also with provisions of governmental codes, ordinance•, and standards whenever applicable. Form No. F_06019B 17.02.02 Rev 17.1 \IIKINCii ® TECHNICAL DATA Page 4 of6 ESFR PENDENT SPRINKLER VKS00 (K14.0) The Viking Corporation, 210 N Industrial Parl< Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlkingcorp.com Visit the Viking website for the latest edlUon of this technical data page: www.vlklnggrouplnc.com Approval Chart 2 (FIi) _......,......_.,.__ _,n,.112...,-. Bue Part SIN NPT Thread Slze Nominal K-factor av.tall Length Number1 Inches I mm U.S. I metric' 10284 VK500 314' I 20mm 14.0 I - 11350 VKSOO 314' I 20mm -I 202 Approved Temperature Ratings A· 165 •F (74 'C) 8 • 205 'F (96 'C) Footnotea 1 Base part number shown. FOf complete part number. refer to the price Mst. Inches mm 2-7/8 73 2-7/8 73 l~::'~..::.J FM Approval•"" (Refer also to Dff'Gn Crtt.rl1 ti.tow.) A1, 81 A1,B1 Approved Finish 1-Braos 'Metric K-Fac1Dr meas<nment shown Is when prMsu-e ls measured In bar. ""1e<1 pressure Is measured In kPa, divide the metric K-Factor shown by 10.0. s This chart shows the FM Approvals available at the time of printing. Other approvals may be ln process. ' FM Approved as a quick response pendent Non.Storage sprinkler and also FM Approved as a quick response pendent Storage sprinlder. Refer to Design Criteria below. DalGN CRl'lmllA • I'll (Alie ,.,_IOApproyal 0111112 _,..,) FM ARPCPYII RtAMlctroaot,. 1. Sprimder VKSOO is FM Approved as a quick response pendent Storage sprinkler as Indicated in the FM Approval Gulde. • For specific apj:Mlcation and Installation requirements. reference the latest appUcable FM Loss Prevention Cata Sheets (lndudlng Data Sheets 2-0 and 8-9). 2. Sprinkler VK.500 Is also FM Approved as a quick response pendent Non-Storage sprinkler as Indicated In the FM Approval Gulde. • Fo, spedfic appf'lcation and tnstallation requirements, reference the latest applicable FM Loss Prevention Cata Sheets (Including Data Sheet 2-0). FM Global Loss Prevention Cata Sheets contain guidelines relating to, but not limtted to: minimum water suppty requirements, hydraulic deslgn, ceiling Slope and obstructions, minimum and maximum a/lowabkt apaclng, and deflector distance bek>w the celling. NOTE: Th• FM lnatallatlon guideline■ may differ from cULua and/or NFPA crtter1.a. IMPORTANT: Always refer to Bulletin Fonn No. F _091699 • Care and Handling of Sprinklers. Viking ESFR Pendent Sprinklers are to be Installed In accordance with the latest edition of Viking technical data, the latest appllcable FM Global Loss Prevention Data Sheets (Including 2-0 and 8-9), the latest standards of VdS, NFPA, and any other Authorities Having Jurisdiction, and also with provisions of governmental codes, ordinances, and stan• dards whenever applicable. Form No. F _060198 17.02.02 Rev 17.1 Page 5 of6 'JIKI~® TECHNICAL DATA ESFR PENDENT SPRINKLER VKS00 (K14.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384--5464 Fax: 269-818-1680 Email: techsvcs@vlklngcorp.com Visit the Viking website for the latest edition of thla technical data page: www.vlklnggrouplnc.com 4. INSTALLATION ----Viking 1pr1nktera are manufactured and teated to meet rigid requirements of the approving agency. The aprlnklera are dealgned to be lnatalled In accordance with recognized Installation standards. System doalgn muat be buod on ESFR design guidelines described In tho Jateat edition of Viki nil Jechnlcal data, ap,P.licable FM Global Losa Prevention Data Sheela, the Jatast NFPA Standards, tho lateat standards of JVdS) Schadonverhutung, the Authorltie• Having Jurladlctlon, and also with the provisions of governmental codas, ordinances, and standards whenever applicable. Deviation from the standards or any alteration to the sprinkler after It JeavH the factory Including, but not limited to: painting, plating, coating, or modification, may render the sprinkler Inoperative and will automatically nullify the approval and any guar- antH made by The Viking Corporation. A. Sprinklers must be handled with care. They must be stored In a cool, dry place In their original shipping container. Never Install sprinklers that have been dropped or damaged In any way. Such sprinklers should be destroyed Immediately. NOTE: Wet pipe systems must be provided with adequate heat. B. The sprinklers must be installed after the piping is in place to prevent mechanical damage. Before installing, be sure to have the appropriate sprinkler model and style, with the correct orifice size, temperature rating, and response characteristics. C. With the sprinkler contained In the plastic protective cap, apply a small amount of pipe-Joint compound or tape to the male threads only, while taking care not to allow a build-up of compound In the sprinkler orifice. D. Uae ONLY sprlnkler wrench 10285W/B or 13635W/B (shown In Figure 1) for lnstalllng ESFR Sprinkler VK500I With the oprlnkler contained In the protective cap, Install the sprinkler onto the piping by applying Iha sprinkler wrench to the aprlnklor wrench nats only, whlla taking care not to damage the sprinkler operating paru. • DO NOT use any other type of wrench, es this could damage the unit. • DO NOT use the sprinkler deflector 0< fusible element to start or thread the sprinkler Into a fitting. • DO NOT exceed 50 ft. lbs. of torque (hand tlght, plus approximately two full turns with the wrench) to Install these sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. E. After Installation, the entire sprinkler system must be tested. The test must be conducted to comply with the Installation Standards. Make sure the sprinkler has been property tightened. If a thread leak occurs, normally the unit must be removed, new pipe-Joint compound 0< tape applied, and then reinstalled. This Is due to the fact that when the Jolnl seal Is damaged, the sealing compound 0< tape Is washed out of the joint. immediately replace any damaged units, using the special sprinkler wrench only. F. After Installation and tutlng and repairing of all leak,, ramovo the protective capo from the sprinklers. DO NOT uoa any type of tool to remove the cap. Remove tho cap by hand: tum It slightly and pull It off the aprlnkler. When removing caps, UH care to prevent dlalodglng or damaging sprinkler ejector aprlng and fusible element. THE CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! G. System design must be based on ESFR design guidelines described In applicable FM Global Loss Prevention Data Sheets, the latest standards of (VdS) SchadenverhOtung, the National Fire Protection Association, and the Authorities Having Jurisdiction. All requirements of recognized sprinkler system design standards apply to systems utilizing Viking ESFR Pendent Sprinklers. NOTE: Viking recommends Jn1talllng one style of aprlnklers (either pendent or upright) throughout ESFR systems. However, provided the fusible elementa are ln1talled within the distance below the celllng allowed by the Installation standardt, and when acceptable to the Authority Having Jurltdlctlon, Viking considers the prectlce of mixing upright and pendent ESFR sprinklers to be acceptable. 5. OPERATION During fire conditions, the heat-sensitive fusible element assembly disengages, releasing the seat and spring assemblies to open the waterway, Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to suppress the fire. Form No. F _060198 17.02.02 Rev 17.1 'JIKI~® TECHNICAL DATA Page 6 of 6 ESFR PENDENT SPRINKLER VKS00 (K14.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlklngcorp.com Visit the Viking website for the latest edition of this technical data page: www.vlklnggrouplnc.com 6. INSPECTIONS, TESTS ANO MAINTENANCE The owner la reeponalble for maintaining the fire protection system and devices In proper operating condition. For minimum maintenance and ln■pectlon requirement■, refer to the NFPA standard that describea care and maintenance of sprinkler system,. In addition, the Authorities Having Jurlsdlctlon may have addttlonal maintenance, tutlng, and Inspection requirements that must be followad. A. The sprinklers must be Inspected on a regular basis for corrosion, mechanical damage, obstructions, paint, etc. The frequency of lnspeellons may vary due to corrosive atmosphere, water supplies, and activity around the device. B. Sprinklers that have been painted 0< mechanically damaged must be replaoed Immediately. Sprinklers showing signs of cor- rosion shall be tested and/or replaced immediately as required. Installation standards require sprinklers to be tested and, if necessary, replaced after a specified term of service. For Viking ESFR Pendent Sprinklers, refer to the Installation Standards (e.g., NFPA 25) and the Authorities Having Jurisdiction 10< the specified period of ttme after which testing and/or replacement Is requ~ed. SprlnkJers that have operated cannot be reassembled or reused, but must be replaced. When replacing sprtnklers, use onty new sprinklers. C. The sprinkler discharge pattern is critical for proper fire protection. Therefore, nothing should be hung from, attached to, or otherwise obstruct the discharge pattern. All obstructions must be Immediately removed or, If necessery, additional sprinklers lnstaned. 0. When replacing existing sprinklers, the system must be removed from service. Refer to the appropriate system description and/ or valve Instructions. Prk>r to removing the system from service, notify aff Authorities Having Jurisdiction. Consideration shoutd be given to employment of a fire patrol In the affected area. 1. Remove the system from service, drain all water, and relieve all pressure on the piping. 2. Using the special sprinkler wrench, remove the old sprinkler and Install the new unit. Care must be taken to ensure that the replacement sprinkler Is the proper model and style, wl1h the correct orifice size, temperature rating, and response charac- teristics. A fully stocked spare sprinkler cabinet should be provided for this purpose. 3. Place the system back In service and secure all valves, Check the replaoed sprinklers and repair all leaks. E. Sprinkler systems that have been subject to a fire must be returned to service as soon as possible. The entire system must be Inspected for damage and repaired or replaced as necessary. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced. Refer to the Authorities Having Jurisdiction for minimum replacement requirements. 7. AVAILABILITY The Viking Model VK500 Sprinkler Is avaHable through a network of domestic and International distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule Of contact Viking direc1ly. Form No. F _060198 17.02.02 Rev 17.1 Replaces Form No. F _060198 Rev 16.1 (Added CCCF approved sprinkler.) ........... As the leading supplier of steel sprir;,kler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength-plus reliable service. You need Bull Moose. 1.083 1.418 1.461 Z.070 1.860 Z.754 1.00 1.00 per lift 70 51 2,Z17 2,534 2,639 • UL listed (US & Canada) and FMlapproved • ASTM A1I35 and A795 Type E, G~ade A Certified (' 1 •1 C~(llplies wi}~ NFPA-13, 13R ar~,14 I 1!l·,1. ·.1 'n USt');rtea;ping r ydrauli'c chjir ~~eristics <:: R of 1o and greater '. l • Al pipe )NOT weld tested siv'e malie"r'ofiieildf!Ph»'e ®7-'.':1 • RED OR BLA[I( PAINTED PIPE. I 11 II ~ APPROVED 1.654 z.m Z.547 3.308 3.468 4.842 1.00 1.00 44 30 Z,353 2,084 2,690 Z,38Z 2,802 Z,481 OTHER BENEFITS/SERVICES: • We have the most stocking locations in the industry, for best delivery and availability • Plain end or roll groove • Eddy1Guard II"' bacterial-resistant internal coating • ~ustom length ;Options Hot dipped galvanization • Reddi-Pipe® red or black pipe eliminates field painting Compatible for use in wet. dry. preaction and deluge sprinkler systems • The only maker with EPDs (to help earn LEED points). Ci] NFSA NFPA' Fig. 200 -"Trimline" Adjustable Band Hanger Size Rang,a -1/2" thru 8" pipe Material -· Carbon Steel, Mil. Galvanized to G90 specifications Function --For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features -- • (1/2" thru 2") Flared edges ease installation for , all pipe types and protect CPVC plastic pipe from abrasion. Captured design ~eeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. 1 • (2'/," thru 8" Spring tension dn nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals -Underwriters' Laboratories listed (1/2" thru W') in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved P/4" thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature -650°F Finish -Mil. Galvanized. For Stainless Steel materi- als, order TOLCQTM Fig. 200WON. Order By --Figure number and pipe size A .. ·,; .,.· . . :: ~-;1 Dimensions • Weights Pipe Rod Size Max. Rec. Size Inch Metric A 8 Load Lbs. 1/2 3/8 8mm or 10mm 3'/a 2•,. 400 3/4 3/8 8mm or 10mm 3'/a 2½ 400 1 3/8 8mm or 10mm 3'/a 25/a 400 1¼ 3/8 8mm or 10mm 3'1, 211. 400 1 'I, I 3/8 8mm or 10mm 37/a 211. 400 2 3/8 8mm or 10mm 4 'I, 3 400 2½. 3/8 10mm 5¼ 4 ,,. 600 3 3/8 10mm 5''• 4 600 3½ 3/8 10mm ?'Is 5'/, 600 4 3/8 10mm 73/a 5 1000 5 1/2 12mm 9'/a 6'/, 1250 6 1/2 12mm 10'/a 6¼ 1250 8 1/2 12mm 13'/• 8¼ 1250 ' ' ·/ B -:- Approx. Length 11 11 12 13 14 15 27 29 34 35 66 73 136 Main Orrice/Manufacluring Facilily, 11/', ~;,np,on f\',~ , eo,o,n 1·11 <12~1,, r-I1 m n1 ,,,99 , ra, 00-' n, 0:13n Customer Service • ')l)J I".\) 'i2CJ..\ www.tolco.com , ---- OLC□-' www.tolco.com _ ,I illdlld of NIBco· , Revision 5/24/2001 Fig. 98: -Rod Stiffener Size Rangn -Secures 3/8" thru 7/8" hanger rod Material -Carbon Steel Function --Secures channel to hanger rod for vertical seismic bracing. ' Finish -Electro Galvanized Note -Available in HOG finish or Stainless Steel materials. Order By --Figure number Thread Rod Cut to Length I . res 3/8" thru 7/8" rod in Dimensions • Weights Material -Carbon Steel Maximum Temperature -750°F Finish -Plain Note -Available in Electro-Galvan1ized and HOG finish or Stainless Steel materials. Order By --Figure number, rod diameter, rod length and finish Fig. 100 -All Thread Rod Full Lengths I Size Range -Secures 3/8" thru 7/8" rod in 1 O' lengths Material -Carbon Steel Maximum Temperature -750°F Finish -Plain Note -Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Orde~ By -· Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F I I Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 4960 4420 ·222 1 '/, 8000 7140 360 11/, 11630 10370 510 Rod Size 3/8 1 /2 5/8 3/4 7/8 II Main Office/Manufacturing Facility• 11/:i 5ar1p,011 /\vr • C01r,,n Cl\ 92~/9 • l'h 909 /3/ o!>!Y:l • ra, !X)-1 /J/ 0130 Customer Service • ~J(J tr~(; 1J:?(i6 1vww.tolco.com Max. Rec. Load Lbs. For Service Temps 650°F 750°F 610 540 1130 1010 1810 1610 2710 2420 3770 3360 ......--...___ 8007957 8020957 SWG 10 8008957 GST 20 8068925 GST 20 SS 8010957 GST 30 I 8009925 GST 25-380 8022925 SWG 25-380 8021957 SWG20 8073925 SWG 20 SS 8139957 SH GST 20 8141957 SH GST 30 8140957 SH GST 20 SS 8142957 SH GST 30 SS 8038957 DSTR 1 8037957 DSTR 1-1/2 8039957 DSTR 516 8045957 DST 516 8046957 TEK 50 8055957 SWDR1 8056957 8WDR 516 8054957 SWDR 1-1/2 8137957 SH DSTR 1 8150922 )(p 20 8153922 )(p 35 8059957 CST 20 8061957 swc 20 X X X X X X X X X X X X X X X X X X X X X X X X CPVC 1-1/2 300 'CPVC 1-1/2 300 2-1/2 850 2-1/2 850 4 1500 I 4 1500 3-1/2 -4.-1500 2-1/2 -3** 1250 I 2-1/2 1250 I 3 1050 4 1500 3 1050 4 1500 4 4 4 1500 4 1500 4 1500 4 1500 2 750 3-1 /2 1250 ®us LISTED 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 0.188 0.250 0.037 0.037 0.037 0.035 0.027 0.043 X X X X X X X X X X X X X X * swb 25-380 Maximum pipe siz~ in composite wood joist allowed by UL is 3-1/2" I SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4" ** SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" -" ** SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3" ' UL and FM tests were performed in compliance with NFPA-13 Standards. 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1475 1.5 1.5 1.5 1.5 1.5 1.5 0.1050 0.1050 0.1050 0.1875 0.1875 0.0600 0.0600 0.0600 0.1050 0.1050 0.1050 3000 PSI 3000 PSI • ,·r r~Buildex Fastening requirement: 5 times weight of water filled schedule 40 pipe plus 250 pounds. www.itwbuildex.com 800-284-5339 S8S26 "'GiS~ TECHNICAL DATA 1 of3 HOLE CUT SYSTEM MODEL V-7XJ SADDLE LET MECHANICAL TEE The Viking Corporation, 210 N Industrial Par1< Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269~18-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION VGS-Model V-n3 Saddle Let sman mechanical tees are available in sizes 1-1/4• tlYough 2-112·. The Models V-n3 mechanical tees provide an easy lake-out of a branch outlet without the need for wekjing. VGS-Med,anicaf Tees are manufac> hxed at IS09001 certified facilities an are designed to conform to ASTM and other standards where applteabte. Threads are NPT per ANSI B120.1. 2. LISTINGS AND APPROVALS c@)a Guide No. VIZM <8> Class 1920 3. TECHNICAL DATA SpecificaUons: Maximum 'A'Oriting pressure: 300 psi (21 bar) The La.tut vos• Technical Data can be acessecl llf: http:llwww.vlldnggruuplnc.com. Scan to visit our Mobile webslte: go:: ~r;:;.~forming lo ASTM A536 I htlp:IM!dnWoup,mol>ilp/~37◄ Standard black finish Hot dipped Zinc gatvanized versions are available (conforming to ASTM A153); when ordering, add a "G" suffix to the Model number. Rubber compound EPDM Grade E conforming to ASTM D2000, AWNA C606, NSF 61 and IAPMO. Nuts and Bolls: Zinc plated, carbon Steel confonning lo ASTM A 183 Grado 2 (UNC nuts and bolts a,e a silver chromate color and ISO are a gold chromate colol) 1.25 x 0.75 (32x20} 1.25 x 1 I32x25) 1.5 X 0.5 (.Or15) 1.SxO.75 140X20l 1.s7i" ;4Dx25: 2x·o.s 1so_x_1s: 2 X 0.75 [50x 201 2x1 :sox 251 2.Sx0.5 [65x 1s: 2.5 X 0.75 [6Sx2:0: 2.Sx 1 :65 X 25: 20-22 17-30' -20-22 (27-30} 20-22 !7-301 .,;oie diameton atlll suggestad hole HW diametel"I. -T: Tako-out (Center of Ml &o itnd of""' to be ~ Form No. F _110515 16.12.08 Rev 16.1 Replaces Form No. F _110515 Rev 15.1 (Added K-facior limlt table and flow data) "'G;S® TECHNICAL DATA 2of3 HOLE CUT SYSTEM MODEL V-7XJ SADDLE LET MECHANICAL TEE The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877.;J84-5464 Fax: 269~111-1680 Email: techsvcs@vikingcorp.com 4. HOLE CUTTING The ho~ method of pipe preparation is required when using mechanical tees, mechanical crosses, and sadd~. The method of pipe preparation requires the cutting or drining of a specified hole size on the centerline of the pipe. Afways use the correct hole saw size as shOYll'l this data sheet and never use a torch for cutting a hate. After the hoh, has been cut an rough edges must be removed and the area 'Mthin Sia• (16 mm) of the hole should be inspeded to ensure a dean smooth surface, free of any indenta- tions or projections that could affect proper gasket sealing. The area within the •A• dimension should also be inspected and must be free for dirt, scale or any imperfection that could alleci proper sealing or assembly or tho fitting. I A I I I : '0,.--.. \: -+: ·-H·-· : , .. ._,_ .. / l W l1l"""J 5. INSTALLATION NOTES: Use a -..rench to hold the threaded outlet in place Wien installing the sprinkter. Teghten the nuts evenly. Form No. F _110515 16.12.08 Rev 16.1 Do not install sprinkler directty into saddle-Lat with 1· outtet. Threaded _ y oul!et_P. Nuts _/'~ Sprinkler - ►•,.~~ 1'. V-72:~ ~~~I~-~,~~!!~~!'! 'JCGSS TECHNICAL DATA 3of3 HOLE CUT SYSTEM MODEL V-7XJ SADDLE LET MECHANICAL TEE The Viking Corporation, 21 D N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269~18-1680 Email: techsvcs@vikingcorp.com 6. FLOW DATA V-7Xl V-7Xl v-n, Flow test da1a has shown that the to1al head loss bet-Neen point A and 8 for the fittings can be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship bek>w 1.5 2.5 Fann No. F_110515 16.12.08 Rev 16.1 t B· 27 27 31 Foonutas for cv values: <>P=O' C..,' a=c..,x,n;r, \Mlere: Q •Aow (GPM) t,P ,. Pressure Dfop (psi) C., • Aow Coefficient Replaces Form No. F_110515 Rev 15.1 (A-d K-factor limit 1able and flow data)