Loading...
HomeMy WebLinkAbout2820 LOKER AVE E; ; CBC2022-0143; PermitBuilding Permit Finaled {City of Carlsbad Commercial Permit Print Date: 03/20/2024 Job Address: 2820 LOKER AVE E, CARLSBAD, CA 92010-6608 Permit No: Status: CBC2022-0143 Closed -Finaled Permit Type: BLDG-Commercial 2090831500 $1,268,978.84 Work Class: Tenant Improvement Parcel#: Valuation: Occupancy Group: B,F-1,M,S-1 #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: Code Edition: 2019 Sprinkled: Yes Project Title: Track#: Lot#: Project#: Plan#: Construction Type:III-B Orig. Plan Check#: Plan Check#: Applied: 05/04/2022 Issued: 07/12/2022 Finaled Close Out: 03/20/2024 Final Inspection: 05/17/2023 INSPECTOR: Kersch, Tim Description: ABSORBTION SYSTEMS: 27,284 SF T.I. -PHASE 1 (NO OCCUPANCY UNDER THIS PERMIT) Applicant: Property Owner: WARE MALCOMB ARCHITECTS NATHAN DEAN TECHBILT INCOME PROPERTIES INC PO BOX 80036 3911 SORRENTO VALLEY BLVD, # STE 120 SAN DIEGO, CA 92121-1456 (858) 638-7277 FEE BUILDING PLAN CHECK SAN DIEGO, CA 92138-0036 (619) 223-1663 BUILDING PLAN REVIEW-MINOR PROJECTS (LDE) BUILDING PLAN REVIEW -MINOR PROJECTS (PLN) CERTIFICATE OF OCCUPANCY COMM/IND Tl -STRUCTURAL FIRE F Occupancies Tl SB1473 -GREEN BUILDING STATE STANDARDS FEE STRONG MOTION -COMMERCIAL (SMIP) Total Fees: $6,255.64 Total Payments To Date: $6,255.64 Contractor: THE WHITING TURNER CONTRACTING CO 3911 SORRENTO VALLEY BLVD, # STE 100 SAN DIEGO, CA 92121-1457 (858) 792-0600 Balance Due: AMOUNT $1,911.13 $194.00 $98.00 $15.00 $2,940.20 $691.00 $51.00 $355.31 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov COVER SHEET FOR CBR2022-0143 BUILDING APPLICATION (B-1) MISSING Building Permit Inspection History Finaled (cityof Carlsbad PERMIT INSPECTION HISTORY for (CBC2022-0143) Permit Type: BLDG-Commercial Application Date: 05/04/2022 Owner: TECH BIL T INCOME PROPERTIES INC Work Class: Tenant Improvement Issue Date: 07/12/2022 Subdivision: PARCEL MAP NO 15692 Status: Closed -Finaled Expiration Date: 05/22/2023 Address: 2820 LOKER AVE E IVR Number: 40422 CARLSBAD, CA 92010-6608 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Relnspection Inspection Date Start Date Status 09/07/2022 BLDG-12 steel/Bond 191118-2022 Cancelled Tim Kersch Relnspectlon Incomplete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency Bond beam. Yes 08/11/2022 08/11/2022 BLDG-21 188995-2022 Partlal Pass Tim Kersch Relnspectlon Incomplete Underground/Underflo orPlumblng Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 08/25/2022 08/25/2022 BLDG•21 189932·2022 Partial Pass Tim Kersch Relnspectlon Incomplete Underground/Underflo orPlumblng Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 08/31/2022 08/3112022 BLDG-12 Steel/Bond 190397-2022 Partial Pass Tim Kersch Ralnapactlon Incomplete Bffm Checklist Item COMMENTS Passed BLDG-Building Deficiency Bond beam. Yes 09/08/2022 0910812022 BLDG-21 191117-2022 Partial Pass Tim Kersch Relnspectlon Incomplete Underground/Underflo orPlumblng Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 09/14/2022 09/14/2022 BLDG-31 191499-2022 Partial Pass Tim Kersch Reinspection Incomplete Underground/Conduit • Wiring Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 09/16/2022 09/16/2022 BLDG-21 191834-2022 Partial Pass Tim Kersch Relnspectlon Incomplete Underground/Unclerflo orPlumblng Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-31 191833-2022 Partial Pass Tim Kersch Rainspactlon Incomplete Underground/Conduit • Wiring Wednesday, March 20, 2024 Page 1 of3 PERMIT INSPECTION HISTORY for (CBC2022-0143) Permit Type: BLDG-Commercial Application Date: 05/04/2022 Owner: TECHBIL T INCOME PROPERTIES INC Work Class: Tenant Improvement Issue Date: 07/12/2022 Subdivision: PARCEL MAP NO 15692 Status: Closed -Finaled Expiration Date: 05/22/2023 Address: 2820 LOKER AVE E IVR Number: 40422 CARLSBAD, CA 92010-6608 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 09/22/2022 09/22/2022 BLDG-21 192337-2022 Partial Pass Tim Kersch Re inspection Incomplete Underground/Underflo orPlumblng Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 09/26/2022 09/26/2022 BLDG•12 Stael/Bond 192642-2022 Partial Pass Tim Kersch Relnspectlon Incomplete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency Bond beam. Yes 09/30/2022 09/30/2022 BLDG-21 193041-2022 Partial Pass Tim Kersch Relnspectlon Incomplete Undarground/Underllo orPlumblng Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 10/14/2022 10/14/2022 BLDG-12 Steel/Bond 194166-2022 Partial Pass Tim Kersch Relnspection Incomplete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency Bond beam. Yes 10/19/2022 10/19/2022 BLDG-12 Steel/Bond 194433-2022 Passed Tim Kersch Complete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency Bond beam. Yes 10/24/2022 10/24/2022 BLDG-12 Steel/Bond 194786-2022 Partial Pass Tim Kersch Relnspectlon Incomplete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 10/27/2022 10/27/2022 BLDG•12 Steel/Bond 195110-2022 Partial Pass Tim Kersch Re Inspection Incomplete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-21 195109-2022 Passed Tim Kersch Complete Underground/Underllo orPlumblng Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes Wednesday, March 20, 2024 Page 2 of 3 PERMIT INSPECTION HISTORY for (CBC2022-0143) Permit Type: BLDG-Commercial Work Class: Ten ant Improvement Application Date: 05/04/2022 Owner: TECH BIL T INCOME PROPERTIES INC Status: Closed -Finaled Issue Date: 07/12/2022 Subdivision: PARCEL MAP NO 15692 Expiration Date: 05/22/2023 IVR Number: 40422 Address: 2820 LOKER AVE E CARLSBAD, CA 92010-6608 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date 11/23/2022 11/23/2022 05/17/2023 05/17/2023 Wednesday, March 20, 2024 BLDG-21 197274-2022 Underground/Underflo orPlumblng Checklist Item COMMENTS BLDG-Building Deficiency BLDG-Flnal Inspection 211277-2023 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final COMMENTS TEXT Status Passed Passed NOTES Created By Angie Teanio 858-264-7738 Ethan Tim Kersch Tim Kersch Passed Passed Yes Yes Yes Yes Yes Created Date 05/16/2023 Complete Complete Page 3 of 3 DATE: 05-20-2022 JURISDICTION: Carlsbad PLAN CHECK#.: CB-CBC2022-0143 • lW INTERWEST A SAFEb1;1lt' COMPANY SET:I PROJECT ADDRESS: 2820 Loker Avenue East 0 APPLICANT 0 JURIS. PROJECT NAME: Absorption Systems-Phase 1 Underground Plumbing and New Internal CMU Mezzanine-TI D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. ~ The check list transmitted herewith is for the applicant's information. The plans are being held at lnterwest until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to the jurisdiction at: D lnterwest staff did not advise the applicant that the plan check has been completed. ~ lnterwest staff did advise the applicant that the plan check has been completed. Person contacted: Nathan Dean Telephone#: 858-638-7222 Date contacted: (by: ) Email: Mail Telephone Fax In Person 0 REMARKS: By: Erich A. Kuchar, P.E. lnterwest Received on: 05-09-2022 ndean@waremalcomb.com Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK#.: CB-CBC2022-0143 JURISDICTION: Carlsbad OCCUPANCY: B, F-1, M, S-1 USE: Office and Lab TYPE OF CONSTRUCTION: III-B ACTUAL AREA: 27,284 sqft of work ALLOWABLE FLOOR AREA: existing STORIES: 2 HEIGHT: unchanged SPRINKLERS?: Yes REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 05-04-2022 DATE INITIAL PLAN REVIEW COMPLETED: 05-20-2022 FOREWORD (PLEASE READ): OCCUPANT LOAD: unchanged DATE PLANS RECEIVED BY ESGIL CORPORATION: 05-09-2022 PLAN REVIEWER: Erich A. Kuchar, P.E. This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2019 CBC, which adopts the 2018 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2018 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: a. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to lnterwest and the Carlsbad Planning, Engineering and Fire Departments. OR; b. Bring TWO corrected set of plans and calculations/reports to lnterwest, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560- 1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to lnterwest only will not be reviewed by the City Planning, Engineering and Fire Departments until review by lnterwest is complete. 2. Plans may be submitted in electronic format, subject to the jurisdiction's approval. If so, they must have restrictions removed from the security settings. Electronic plans with restrictions to markups, printing, or stamping will not be approved. Electronic plans must be submitted back to the jurisdiction's building department and will then be routed to lnterwest. ONLY submit FULL complete and combined sets of plans, uploading multiple single sheets will not be allowed. Make sure all plans and calc packages, spec. reports, etc: are labeled clearly and can be read what they are and WHAT SUBMITTAL they go with. DO NOT SEND documents directly to lnterwest as they will not be accepted. 3. Provide item-by-item responses on an 8-1 /2-inch by 11-inch sheet(s) clearly and specifically indicating where and how each correction item has been addressed (vague responses, such as "Done" or "See plans," are unacceptable). 4. Please provide a response list indicating where each correction item has been addressed on the plans. I.e., specify the plan sheet, note, or detail number, calculation page, etc., where the item is corrected on the plans. 5. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: □Yes □ No 6. The jurisdiction has contracted with lnterwest, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact lnterwest. Thank you. BUILDING COMMENTS Plan Check Engineer: Erich A. Kuchar, P.E. Set: I 7. No Comments as submitted. PLUMBING COMMENTS Plan Check Engineer: Martha McNicholas, P.E. Set: I 1. Floor drains and floor sinks are missing the required vents. Please provide a separate vent connection to each fixture upon next submittal per CPC Chapter 9. 2. No vents piping was provided on plans Provide vent piping and sizes on plumbing plans. Each plumbing fixture trap, except as otherwise provided in this code, shall be protected against siphonage and backpressure, and air circulation shall be ensured throughout all parts of the drainage system by means of vent pipes installed in accordance with the requirements of CPC 901.2 3. The size of vent piping shall be determined from its length and the total number of fixture units connected, in accordance with Table 703.2. Vent pipes from fixtures located upstream from pumps, ejectors, backwater valves, or other devices that obstruct the free flow of air and other gases between the building sewer and the outside atmosphere shall not be used for meeting the cross- sectional area venting requirements of this section. Please provide accordingly. 904.1 4. Notes 2 and 4 on plans uP001 specified two different type of materials for sewer and vent. If PVC DWV piping will be used, installations shall be in accordance with the firestop protection requirements in the California Building Code. Clarify and provide waste and vent materials to be used on this project. General or typical notes are not acceptable CPC 701.0 & CPC 903.0 5. Only waste riser was provided. Provide riser diagram for the waste and vent systems. The waste system shall extend to the property line. The riser diagram shall indicate all the fixtures served, the pipe sizes, and the fixture unit count on each leg of pipe. 6. Materials exposed within ducts or plenums shall have a flame-spread index of not more than 25 and a smoke-developed index of not more than 50 where tested in accordance with ASTM E84 or UL 723. These tests shall comply with all requirements of the standards to include the sample size, both for width and length. Plastic pipe shall not be tested filled with water. Provide accordingly on plans. note on plans. CPC 903.1 7. Please show the slopes for all horizontal waste pipes within the plumbing plans. Note: All waste pipes that are smaller than 4" must have a minimum slope of 2%. Please show on the plans. CPC 708.1 8. Please provide plumbing roof plan on next submittal showing the VTR locations. Make sure the proper 10' clearances are provided from any forced air intakes. 9. Provide floor drains on plans and details the floor drain trap seal is to be maintained. CPC 1007.0 10. Trap primers are required to be used for all infrequent floor drains (i.e. trap guards are not approved). Please provide on plans. CPC 1007.0 Building Permit Finaled Revision Permit Print Date: 03/20/2024 Job Address: 2820 LOKER AVE E, CARLSBAD, CA 92010-6608 Permit No: Status: {"Cityof Carlsbad PREV2022-0157 Closed -Finaled Permit Type: BLDG-Permit Revision Work Class: Commercial Permit Revision Parcel#: 2090831500 Track#: Valuation: $1,268,978.84 Lot #: Occupancy Group: B,F-1,M,S-1 #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: Code Edition: 2019 Sprinkled: Yes Project Title: Project#: Plan#: Construction Type: 111-B Orig. Plan Check#: CBC2022-0143 Plan Check #: Applied: 12/21/2022 Issued: 01/25/2023 Finaled Close Out: 03/20/2024 Final Inspection: INSPECTOR: Description: ABSORBTION SYSTEMS: 27,284 SF T.I. -PHASE 1 (NO OCCUPANCY UNDER THIS PERMIT) Applicant: WARE MALCOMB ARCHITECTS NATHAN DEAN 3911 SORRENTO VALLEY BLVD, # STE 120 SAN DIEGO, CA 92121-1456 (858) 638-7277 FEE BUILDING PLAN REVIEW-Revisions Property Owner: TECHBILT INCOME PROPERTIES INC PO BOX 80036 SAN DIEGO, CA 92138-0036 (619) 223-1663 FIRE Plan Review (per hr -Regular Office Hours) Total Fees: $720.00 Total Payments To Date: $720.00 Building Division Contractor: THE WHITING TURNER CONTRACTING CO 3911 SORRENTO VALLEY BLVD, # STE 100 SAN DIEGO, CA 92121-1457 (858) 792-0600 Balance Due: AMOUNT $480.00 $240.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov Ca:trof Carlsbad PLAN CHECK REVISION OR DEFERRED SU BM ITT AL APPLICATION Development Services Building Division 1635 FaradayAvenue 442-339-2719 www.carlsbadca.gov B-15 Original Plan Check Number _c_sc_20_2_2-0_1_43 _____ Plan Revision Number 't(<B)-ZOt,;2-0 / 6'] Project Address 2820 LOKER AVE. EAST, CARLSBAD, CA 92010 General Scope of Revision/Deferred Submittal: DEL TA 3 & 4 REVISIONS FROM PERMITTED SET FOR PHASE 1. INCLUDES CHANGES MADE TO ADDITIONAL UNDERGROUND PLUMBING, ROOF FRAMING FOR FUTURE UNITS, AND TRENCH DRAIN DETAILS. CONTACT INFORMATION: Name NATHAN DEAN -WAREMALCOMB ARCHITECTS Phone ..:,.;858:=....:-5=0D-4:....;..:::6..:..:1Be.__ ____ Fa,..__ _________ _ Address 3911 SORRENTO VALLEY BLVD, SUITE 120 City SAN DIEGO Zip 92121 Email Address NDEAN@WAREMALCOMB.COM Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 . Elements revised: b2I Plans b2I Calculations D Soils O Energy D Other 2. 3. Describe revisions in detail List page(s) where each revision is shown PLEASE REFER TO THE REVISIONS SUMMARY ON NEXT SHEETS, WITH LINE ITEM PER SHEET. THE CHANGES INCLUDE A CLOUD AND DEL TA INDICATOR ON PLANS. DELTAS 3 & 4 HAVE BEEN INDICATED FOR EACH PERTAINING SHEET. SUPPLEMENTAL STRUCTURAL CALCULATIONS. 4. Does this revision, in any way, alter the exterior of the project7 5. Does this revision add ANY new floor area(sJ? D Yes 6. Does this revision affect any fire related issues? D Yes 7. Is this a complete set? b2] Yes D No .e5'Signature ~~ D Yes 1;21 No QI No b2j No Date 1211912022 1635 Faraday Avenue, Carlsbad, CA 92008 Ph: 442-339-2719 Email: building@carlsbadca.gov www.cartsbadca.gov .. CITY WISEMAN+ROHY STRUCTURAL ENGINEERS SUPPLEMENTAL STRUCTURAL CALCULATIONS 9915 Mtra Mesa Blvd. TEL. (858) 536-5166 FOR ABSORPTION SYSTEMS PHASE 1 DELTA 4 2820 LOKER AVE. EAST CARLSBAD, CA 92010 DECEMBER 8th, 2022 W+R Job #22-005 PREV2022-0157 2820 LOKER AVE E Suite 200 ABSORBTION SYSTEMS: 27,284 SF TI. -PHASE 1 (NO OCCUPANCY UNDER THIS PERMIT) WRENGINEERS.COJ 2090831500 CBC2022-0143 12/22/2022 PREV2022-0157 : .. ( li i . f\• I • .. BY__.__.,._._,_.___. 1DATE \'2/fj WISEMAN.+ ~U)HY .. Jr_,ygpQ~ .E"'-'"HR.S SHEET.Nb; OF.:_·. __ _ JOBNq. ······22...oos. -~. .... ' • ··p p /.$ '1_◊,b :·,tf · .... , . --: ------r. ···-----.. ---··-·--.... .. -.. -.. ---~---~-•~-•-...... -.. , ,, ... -l-... ,, ,. .. , .... -.. , ...... . : W:t>~ "'lb f'~~ .. Jb:1. ::&>n. -p~-.,-po11 M ~ t"1• \.Ji;.; ::: ····2 • ,·..::· ! -... ,...:t' ,,-· 1-········ ... Pp.,..-... ..,., . ~ ,op1.F. ·l ···················~~K1' •. WC>$";ri"._,£~ • ......... _ ~"P ;;:4b~·~·-·!..::.·.···························· ·:-· I .. -·---+-I ··-···---······--·--···-··-·--············-.\ ........ ,_,,. .................. ' ....................... 1 .... .... ---· ------------------:---. ---- ···i··· .. ! . .... J. ...................... i ......... . ..... j ..... , -----··••:••--················· .. ···•• .. •· 1.:.rii ~ :iJ\... ~ "hi>"" \ ... --. ./. ............... . i- . . I . . . . .... J ... l ..... . ·Y"'"·· o •l. r ~:·;;~~o ._ : i . ·•rn_., __ II ~g. · ·'Z--flo'i . . : w/ ~o! -6~~,.,;.-·o·., .. ,.:, '"".>.:~¢i6·· ✓Q.,i ---····~1--·-------~-.. ------·· .. ,. ·-·-··-·--~-·-.. ···-· j l ......• ..,". •••••I .. •••••••••-••-•-•••-•--•••••-••••·••••• ' • ~• • ,_.., -~• ··---•-•-· -•·-•--·•·•·•-•"'" • • • ••• , • .,,.,._,•~••• • -c---....... -.--••-•• ••• • , ... .f ••-~••••••••• • • ·······-·_j_ ---F- i --- . . ' I -----~-------t- r ! 1-----.. L .... : I ! i : 1 :--i i j i 1 ' 1---l---- 1 i J I SK-1 NM Absorption Systems Ph1 Dec 9, 2022 at 8:27 AM 22-005 Roof SUppotts Ph1 (w. OF #2).r2d SK-2 NM Absorption Systems Ph1 Dec 9, 2022 at 8:27 AM 22--005 Roof Supports Ph1 (w. OF #2).r2d SK-3 NM Absorption Systems Ph1 Dec 9, 2022 at 8:28 AM 22-005 Roof Supports Ph1 (w. DF #2).r2d Loads: BLC 1, DL Envelope Only Solution NM 22-005 -401b/ft ~ ~am -~N4 -910Ib -401b/ft ~ ~-00llilillllil1llillil~-~ 1 ~ SK-1 Absorption Systems Ph1 Dec 9, 2022 at 8:33 AM Roof Supports Ph1 (w. DF #2).r2d Loads: BLC 2, RLL Envelope Only Solution NM 22-005 -401blftmnTTTTTTTrFTTT1"TTTTTTITTTTTITTT7.TTTTTTTTTTTTrTT"nrrrrTTTTTTTTT".....-rn.rn-t"TTTTT"1""'T"...,..,..,..,r'TT"T"1....-rr'T"T'TT'TTTT'> ·--ll!llil1lilllil1~-L~WJU~N4 -401Wftn-t"T1M"7TT-rr.Tr.-rT7rrmTTT"TT1"TTT"TT"rr-TT"T,--r-M""T-rn-T"...,..,....n-rr,,.....,....,..,.,.,......,..,..~~-~.-n-r,.--m-,,.,..,.,-.,..,...., pi-m1u•1-~N2 SK-2 Absorption Systems Ph1 Dec 9, 2022 at 8:34 AM Roof Suppons Ph1 (w. DF #2).12d Beam: Next Worst EF Shape.; 4X6 Material: DF#2 length: 8 ft I Joint: N3 J Joint: N4 Envelope Code Check: 0.745 (LC 1) Report 13ased On 1 O Sections A-----------lb -538. 715 at 8 ft 0.939 at 4.444 ft M lb-ft f(y} -0.939 at 4A44 ft -1380.178 at 4.444 ft fa -----------ksi o-,' ,-, ' ,-, ' In -0.192 at 4.444 ft AWC NDS-18: ASD Code Check Max Bending Check 0.745 (LC fl.1ax Shear Check 0.187 (LC 3) Max Defl Ratlo U491 Location 4.04 ft location 8 ft Equation 3.9-3 CD 0,9 RB 6.565 Cr 1 Cfu 1 Fe' Ft' Fb' Fv' E' (ksi} 0.558 0673 1.049 0.225 1600 Cm 1 1 1 1 1 Ct 1 1 1 1 1 CL 0.997 CP 0,418 CF 1.1 1.3 1,3 Locatlon 4,04 ft Span 1 Out Lb 8 ft le/d 27.429 Sway No Le-Bending Top Le-Bending Bot 8 ft 8ft In 8ft 17.455 No Beam: EF 1.2 or 1.3 SQap~ •4X8 Material: DF#2 Length: 8 ft I Joint: N1 J Joint: N2 Envelope Code Check: 0,811 (LC 1) Report Based On 1 O Sections A-----------lb 0.9 at 4.444 ft f(y) ksl -0.9 at 4.444 ft M799.67 at 8 ft M lb-ft • M2298,608 at 4.444 ft fa -----------ksi o-, ,-, ,-, ,-, , In -0.137 at 3.556 ft AWC NDS-18: ASD Code Check Max Bending Check 0.811 (LC 11,Jax Shear Check 0.233 (LC 1) Max Def! Ratio U690 Location 4.04 ft Location 8 ft Equation 3.9-3 CD 0.9 RB 7 .538 CL 0.995 Cr 1 Cfu 1 CP 0.434 Fe' Ft' Fb' Fv' E' (ksil 0.554 0.621 1.048 0.162 1600 Cm Ct CF 1 1 1.05 1 1 1.2 1 1 1.3 1 1 1 1 Location 4.04 ft Spali 1 Out Lb 8ft le/d 27.429 Sway No Le-Bending Top Le-Bending Bot 8 ft 8 ft In 8ft 13.241 No